I have been utilizing a Dataflow for several years to transform web log files (.txt format) through multiple Power Query steps, ultimately creating structured tables for Power BI reporting. The raw dataset comprises approximately 20 GB or 150 million rows.
This Dataflow Gen1 was consuming substantial resources from my F2 capacity. Concerns about Dataflows Gen2 expense prompted investigation into performance differences when implementing identical queries in a new Gen2 version.
Microsoft introduced a native Fabric artifact in 2025: Dataflow Gen2 with CI/CD capabilities offering enhanced functionality.
Migrating between generations has become straightforward through the options menu “Saving as Gen2” feature for both Gen1 to Gen2 and Gen2 to Gen2 CI/CD transitions.
Refresh Time Comparison
| Version | Low | High | Average |
|---|---|---|---|
| Gen1 | 49 min | 52 min | 51 min |
| Gen2 | 32 min | 34 min | 33 min |
| Gen2 CI/CD (scale on) | 70 min | 74 min | 72 min |
| Gen2 CI/CD (scale off) | 34 min | 39 min | 36 min |
Gen2 demonstrates the fastest refresh performance. Gen2 CI/CD speed varies depending on scale settings configuration. When enabled, scale settings may enhance or diminish performance based on data sources — in this case, SharePoint text files experienced negative effects with scaling activated.

Compute Cost Comparison (CUs)
| Version | Low | High | Average |
|---|---|---|---|
| Gen1 | 27,255 | 27,563 | 27,409 |
| Gen2 | 45,096 | 46,736 | 45,916 |
| Gen2 CI/CD (scale on) | 22,142 | 22,526 | 22,334 |
| Gen2 CI/CD (scale off) | 17,498 | 17,704 | 17,601 |
The traditional Gen2 version incurs the highest costs despite superior speed. Notably, the new Gen2 CI/CD dataflow is now much cheaper than the old Gen1 and it is also very fast.
Recommendations
Testing refresh times and CU consumption before migration ensures expectations align with actual performance. Gen2 CI/CD appears positioned to become the standard implementation due to superior cost efficiency compared to previous generations.