Power BI January 25, 2025 · 4 min read

Comparing cost of Dataflows Gen1 vs. Gen2 vs. Gen2 CI/CD in Power BI and Fabric

A real-world comparison of refresh times and CU costs between Dataflow Gen1, Gen2, and the new Gen2 CI/CD in Power BI and Fabric.

Gregor Brunner Gregor Brunner
Comparing cost of Dataflows Gen1 vs. Gen2 vs. Gen2 CI/CD in Power BI and Fabric

I have been utilizing a Dataflow for several years to transform web log files (.txt format) through multiple Power Query steps, ultimately creating structured tables for Power BI reporting. The raw dataset comprises approximately 20 GB or 150 million rows.

This Dataflow Gen1 was consuming substantial resources from my F2 capacity. Concerns about Dataflows Gen2 expense prompted investigation into performance differences when implementing identical queries in a new Gen2 version.

Microsoft introduced a native Fabric artifact in 2025: Dataflow Gen2 with CI/CD capabilities offering enhanced functionality.

Migrating between generations has become straightforward through the options menu “Saving as Gen2” feature for both Gen1 to Gen2 and Gen2 to Gen2 CI/CD transitions.

Refresh Time Comparison

VersionLowHighAverage
Gen149 min52 min51 min
Gen232 min34 min33 min
Gen2 CI/CD (scale on)70 min74 min72 min
Gen2 CI/CD (scale off)34 min39 min36 min

Gen2 demonstrates the fastest refresh performance. Gen2 CI/CD speed varies depending on scale settings configuration. When enabled, scale settings may enhance or diminish performance based on data sources — in this case, SharePoint text files experienced negative effects with scaling activated.

Scale settings in Dataflow Gen2 with CI/CD

Compute Cost Comparison (CUs)

VersionLowHighAverage
Gen127,25527,56327,409
Gen245,09646,73645,916
Gen2 CI/CD (scale on)22,14222,52622,334
Gen2 CI/CD (scale off)17,49817,70417,601

The traditional Gen2 version incurs the highest costs despite superior speed. Notably, the new Gen2 CI/CD dataflow is now much cheaper than the old Gen1 and it is also very fast.

Recommendations

Testing refresh times and CU consumption before migration ensures expectations align with actual performance. Gen2 CI/CD appears positioned to become the standard implementation due to superior cost efficiency compared to previous generations.